Low phase noise
Wide working temperature range
Low power consumption
Low sensitivity to mechanical vibration
|
SPECIFICATIONS
Parameter
|
Symbol
|
Conditions
|
Value
|
Unit
|
Remark
|
|
|
|
Min
|
Norm
|
Max
|
|
|
Frequency range
|
fo
|
|
|
10
|
|
MHz
|
|
Aging
|
Per day
|
Af/fo
|
after 30 days of continuous
|
|
|
+0.1
|
ppb
|
|
Per month
|
continuous
|
|
|
±10
|
ppb
|
|
Per year
|
work
|
20
|
|
50
|
ppb
|
|
Phase noise
|
L(f)
|
10 Hz
|
-140
|
|
-130
|
dBc/Hz
|
for fo = 10
|
100 Hz
|
-155
|
-150
|
MHz
|
1 kHz
|
-160
|
-155
|
|
10 kHz
|
-165
|
-158
|
|
Allandeviation
|
|
12
|
2
|
|
5
|
E-12
|
|
Frequency deviation in operating temperature range
|
Af/fo
|
-60° ÷ +70
|
|
|
50
|
ppb
|
|
Frequency deviation from supply voltage change
|
Af/fo
|
12 V 10%
|
|
|
0.5
|
ppb
|
|
|
RF output
|
Uo
|
Rh = 50 Ohm
|
450
|
500
|
550
|
mV
|
|
Tuning range
|
|
Uynp = 0 ÷ 8V
|
0.5
|
|
|
ppm
|
Positivetilt
|
|
Supply voltage
|
Vcc
|
|
10.8
|
12.0
|
13.2
|
V
|
|
Warm-up time to 1-7
|
|
t = 25
|
|
|
3
|
min
|
|
Power
|
warm-up
|
P
|
|
|
|
1.5
|
W
|
|
Consumption
|
Steady state
|
P
|
t = 25
|
|
|
0.25
|
W
|
|
Environment temperature
|
Storage
|
-60 ÷ +85
|
Operating
|
-60 ÷ +70
|
Vibrations
|
1-2000 Hz, 10g
|
Mechanical shock
|
150 g, 0,3 - 1 ms
|
Humidity
|
100% by 35
|
|
|