• Frequency 100 MHz
• Low phase noise
• Low power consumption
• Small dimensions
SPECIFICATIONS
Parameter
Symbol
Conditions
Value
Unit
Remark
Min
Norm
Max
Frequency range
fo
100
MHz
Aging
Per day
Af/fo
After 30 days of
2
ppb
Per month
continuous work
40
Per year
Phase noise
L(f)
10 Hz
-100
dBc/Hz
For
100 Hz
-130
fo = 100 MHz
1 kHz
-160
10 kHz
-165
Level of incidental constituents
dBc
Allan deviation
11
5
E-11
Frequency deviation in opetating temperature range
-10îÑ-^+60°Ñ -40°Ñ ÷ +70°Ñ
±50 ±100
ppb ppb
Frequency deviation from supply voltage change
12 V ±10%
2.0
RF output
Uo
Rh = 570 6
570
600
650
mV
Tuning range
Uynp = 0 ÷ 8V
±1.0
ppm
Positive tilt
Supply voltage
Vcc
10.8
12.0
13.2
V
Warm-up time to 1Å-7
t = 25°Ñ
3
min
Power
warm-up
P
2.2
W
Consumption
Steady state
0.45
Environment temperature
Storage
-60°Ñ ÷ +85°Ñ
Operating
-40°Ñ ÷ +70°Ñ
Vibrations
1 - 500 Hz, 5g
Mechanical shock
75 g, 1 - 5 ms
Humidity
98% by 35°Ñ